DAIRY SELECTION PROGRAM.

Dairy Cooling Towers Performance          
at 30m3/m2  3.05 m/s    87 pa    35/29.5/22oC          
                 
Model
Water Flow (l/sec)
Motor
kW / usage
Shaft (mm)
RPM
Airflow (m3/sec)
Multiwing Fan Selection
Daily Milk Volume (litres)
MA 6 / 6 3 0.37 0.190 19 930 1.1 500/4-4/40/8D 3000
MA 9 / 6 7 0.55 0.380 19 930 2.47 810/6-9/25/4Z 8000
MA 12 / 6 12 0.75 0.733 24 970 4.4 810/6-9/32.5/4Z 14,000
MA 18 / 6 24 2.20 2.160 28 940 9.9 1200/3-6/32.5/7X 29,000
                 
        SINGLE PHASE MOTORS    
                 
MA9/6 7 0.37 0.380      5/8" 930 2.36 810/6-9/25/4ZR 8000
MA12/6 12 0.75 0.64      5/8" 1440 4.3 810/3-9/22.5/4ZL 14000

 

INSTRUCTIONS:

 

STEP 1: CLIENT DETAILS

  • CONTACT NAME
  • ADDRESS
  • SUBURB
  • TELEPHONE AND FACSIMILE NO.

STEP 2: ENTER CLIENTS TOTAL VOLUME OF MILK IN LITRES FOR BOTH MILKINGS IN ONE DAY.

STEP 3: ENTER WATER TO MILK RATIO THE NORM BEING 3:1 CLICK ON SQUARE AND AN ARROW SHOULD APPEAR, CLICK ARROW AND RATIO REQUIRED.

STEP 4: CLICK ON DURATION REQUIRED
REMEMBER THAT THE TOTAL VOLUME OF WATER MUST BE PASSED OVER THE COOLING TOWER AT LEAST 4 TIMES, THEREFORE WE RECCOMEND THE USE 1 HOUR.

STEP 5: ENTER START & FINISH TIMES, CLICK ON EACH AND ENTER YOUR REQUIREMENTS. THIS WILL HELP INSTALLER OF TIME CLOCK.

RESULTS:

FROM THE INFORMATION YOU HAVE ENTERED THE FOLLOWING INFORMATION WILL BE AUTOMATICALLY SELECTED.

  • TANK STORAGE VOLUME.
  • PUMP MIN FLOW RATE.
  • COOLING TOWER REQUIRED INCLUDING:
    • SIZE,
    • DIAMETER,
    • HEIGHT
    • MOTOR kW.

SHOULD YOU REQUIRE FURTHER INFORMATION
E-MAIL: info@lakesidect.com.au

 

Lakeside Cooling Towers

Lakeside Cooling Towers (Australasia) Pty Ltd
3/198 Whitehorse Rd
Blackburn VIC 3130
Australia
Telephone:+61 03 9877 5066
Facsimile:+61 03 9877 5177
Email: info@lakesidect.com.au

Go Top
 

 

Copyright © 2000 Lakeside Cooling Towers (Australasia) Pty Ltd.  All Rights Reserved.